../_images/packages_icon.png

5.2. PackagesΒΆ

The package library lists all the Power switches: discretes & modules casing/packages.

Each package entry contains the package dimensions, mass and isolation voltage.

These quantities are used in different ways in a design evaluation.

  • Dimensions (x, y ,z)

    are the external dimensions of the package. The package is assumed to be rectangular block shaped. The package volume is considered in the macrocell volume after an evaluation.

  • Package area (x * y)

    is used to check if the total package area of the module is smaller than the cooling system surface. In the case of auto-design, the package area is used to design the cooling system dimensions. For example, a fin heatsink baseplate area needs to be larger than the package area of all the modules used.

  • Thermal dissipation area (\(S_{Dissipation}\))

    is always lower than the package area. It is used to estimate the contact area between the package and the cooling system. If a thermal interface is used, the thermal resistance of this thermal interface is calculated based on this thermal dissipation area.

    \[R_{th(c-s)} = S_{Dissipation} \cdot R_{th Interface}\]

    where \(R_{th Interface} [K.m^2/W]\) is the thermal interface per surface unit

  • Isolation voltage

    If the value is above 0, the package is considered isolated. If the package is NOT isolated, an insulating thermal interface must be used.

../_images/package_dimensions.svg